BRMGQ - AMERICIUM 241 CELL MODULE FOR THE M43A1 DET

  • MSDS: BRMGQ
  • Manufacturer: BRUNSWICK CORP DEFENSE DIV
  • Product Name: AMERICIUM 241 CELL MODULE FOR THE M43A1 DET
  • National Stock Number: 6665-01-105-5623
Product Identification

Product ID:AMERICIUM 241 CELL MODULE FOR THE M43A1 DET
MSDS Date:04/18/1984
FSC:6665
NIIN:01-105-5623
MSDS Number: BRMGQ

Responsible Party
BRUNSWICK CORP,DEFENSE DIV
2000 BRUNSWICK LANE
DELAND, FL 32724
US

Emergency Phone: 904-738-1001

Info Phone: 904-736-8460

Preparer: PHILLIP M. EDWARDS

Cage: 52973

Contractor
BRUNSWICK CORP,DEFENSE DIV
DELAND, FL 32724 US

Telephone: 904-738-1001

Cage: 52973

Ingredients

AMERICIUM 241 250 UCI.

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:UNKNOWN IARC:UNKNOWN OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY CAUSE RADIATION BURNS,
CATARACTS. CHRONIC: MAY CAUSE CANCER. THE LOW LEVEL OF RADIATION
ENVOLVED IS UNLIKELY TO CAUSE SIGNIFIGANT HEALTH PROBLEMS EXCEPT IN
EXTREME OR UNUSUAL CONDITIONS.
Explanation of Carcinogenicity:RADIOACTIVES ARE KNOWN CARCINOGENS.
Effects of Overexposure:REDDENING OF SKIN, BURNS, BLURRING OF VISION,
HAIR LOSS, NAUSEA, VOMITING.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. EYES: FLUSH WITH WATER FOR
15 MINUTES. SKIN: REMOVE CONTAMINATED CLOTHING. WASH WITH SOAP AND
WATER. INGESTION: DO NOT INDUCE VOMITING. IN ALL CASES GET
IMMEDIATE MEDI CAL ATTENTION. ALWAYS NOTIFY RECEIVING MEDICAL
FACILITY OF POSSIBLE RADIOACTIVE CONTAMINATION OF VICTIM.

Fire Fighting

Extinguishing Media:USE MAEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE GEAR. STAY UPWIND TO PREVENT POSSIBLE CONTAMINATION
FROM RADIOACTIVE MATERIAL.
Unusual Fire/Explosion Hazard:CONTAINS A RADIOACTIVE MATERIAL WHICH IF
RELEASED TO ENVIRONMENT POSES A CONTAMINATION HAZARD; LOW HEALTH
RISK.

Accidental Release

Spill Release Procedures:NOTIFY RADIATION SAFETY OFFICE. ISOLATE AREA.
DENY ENTRY. WEAR PROPER PROTECTIVE CLOTHING. SWEEP UP MATERIAL AND
PLACE IN A DOT APPROVED CONTAINER FOR LATER DISPOSAL. ENSURE AREA
IS FREE OF RADIOACTIV E CONTAMINATION PRIOR TO RELEASE OF SPILL
AREA.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:PROTECT FROM PHYSICAL DAMAGE.
Other Precautions:NONE NORMALLY REQUIRED.

Exposure Controls

Respiratory Protection:NONE NORMALLY REQUIRED. IF DEVICE IS BROKEN, USE
NIOSH/MSHA APPROVED RESPIRATOR WITH HEPA FILTER OR IF INVOLVED IN A
FIRE USE SELF-CONTAINED BREATHING APPARATUS.
Ventilation:NONE NORMALLY REQUIRED.
Protective Gloves:RUBBER IF DEVICE BROKEN; OTHERWISE NONE
Eye Protection:SAFETY GLASSES IF DEVICE IS BROKEN
Other Protective Equipment:IMPERVIOUS CLOTHING IF DEVICE IS BROKEN;
OTHERWISE NONE NORMALLY REQUIRED.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING.
Supplemental Safety and Health
MFR/ARMY MSDS OF LITTLE VALUE. HMIS TECHNICIAN USED "PATTY'S" AND
"SIGMA-ALDRICH" TO SUPPLEMENT DATA. MSDS HEALTH EFFECTS ARE WORSE
CASE IN THE EVENT DEVICE IS BROKEN OR INVOLVED IN A FIRE. IN NORMAL
USE THERE IS LITTLE DANGER TO SAFETY AND HEALTH DUE TO THE MINUTE
AMOUNT OF RADIOACTIVE INVOLVED.

Chemical Properties

HCC:A2
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CHEMICAL AGENT ALARM CONTAINS DETECTOR CELL
CONTAINING AM-241.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH TITLE 10 CODE OF
FEDERAL REGULATIONS, DOD REGULATIONS, AND APPLICABLE STATE
REGULATIONS FOR THE DISPOSAL OF RADIOACTIVE MATERIALS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.